The time that hold clip is less. Mean machine damping faster. Optimal is to be able to pass outfit clip to complete 5 treatment. Because accurate treatment is divisional,opened prior operation and precision work. Make the effect double. Graph 1 mix with huge tigidity reduce by calorific the error that cause regards research and development as the target: Mikromat 12V of accurate machining center pursues the Mikromat 12V that 2 use belts measure horny boring milling head and Germany fertile very special company cutting tool undertakes inverting treatment comes from heart is tired this pausing manufacturer Mikromat is famed with its coordinate boring machine. Its have the tall accuracy of its product lead dominant position. In a few years of in the past, mikromat company still was developed those who be used at holding clip is full automatic much and milling and auger cut facility (ideal is 5 treatment) , achieved extraordinary accuracy (graph 1) . The key of research and development depends on production giving huge tigidity and the effect that reduces the breakdown place generation that causes by heat. Control measure through taking structure and temperature especially, prevented from this and those who cause curve a phenomenon, this makes in be being operated actually, the machine is sharp when temperature changes the ground from which expand equably to each direction. Have the aid of is checked at dimension and the electron is corrective and OK very good control heat expands. The error that enhance treatment definition and spots a likelihood is the smallest to fabricating charge change, increase quiet drive, the requirement of wearability and dependability is in ceaseless promotion. To satisfy this one requirement, mix dimension public errand and appearance positional error is the smallest the pressure that turn exists continuously. In addition, be aimed at high accuracy treatment, mikromat company still produced perpendicular machining center. The knife head that differs through changing, can use at perpendicular treatment operation not only, also can use at horizontal treatment, to 5 treatment. Use this kind of configuration to be able to reach highest definition. Catching those who want the introduction is a kind of new treatment method, the improvement that it can last is accessible treatment precision and spot the error that gives a possibility, hanging the error that causes as a result of pollution when clinometer head for instance. Operate in the Mikromat 12V that contains milling head of the boring that measure part and Sinumerik 840D the 180 ° inverting that drill completes on equipment is machined (the definition that graph 2) can reach should produce a condition in its next undertaking that discuss. · uses Germany fertile very special company lengthen bores hole the treatment of high accuracy inverting of aperture of the tool bearing that finish. · is used through mixing measure a head to enhance definition -- the radio of company of Lei Ni carry on measures head RMP60 -- use at allowing to decide deep bore (homocentric degree, be apart from) . What use fertile very special of the company bore hole the tool is K29230, take S162 of head of odd blade boring cutter.

5-205Multibore, grow 570mm, weigh 20kg, take but dislocation razor blade, radius 0.

1mm, rotate speed 180r/min, feed 11mm/min. Be in a hole that a diameter drills to be 175mm about inside GG40 cast-iron case. Whole process makes an appointment with 30 minutes more than continuously. The machine places what undertaking air adjustment to assemble a workshop inside. Except use measure a head to undertake corrective the treatment process that the inverting beyond machines includes the following measure (graph 3) : Graph 3 treatment are tectonic: Producing a room the inverting of aperture of run the drilling tool into the well is machined 1.

Measure auxiliary tool reference plane circumferential reach end panel milling 2.

Use the central coordinate that measures a hole that computational car will drill. Clinometer position head 180 ° . 3.

Use fertile very special boring lever bore, clinometer head position 180 ° . 4.

Use the central coordinate that measures a computation to go out to already drilled good hole. Make an appointment with 10µm to retrorse shift by Z of edge of cutting tool dimension above all. Feel Y at the same time, z just measures a range to two when go up and computation gives the space that they reach aperture center. Clinometer position head 180 ° . 5.

The central coordinate that according to the 2nd pace computation gives is used fertile very special boring lever bore, not farther calibration. The distance between the position that the position of X axis reachs with the 3rd pace is 1450mm about. Clinometer head 0 ° . 6a.

Use the central coordinate that measures a computation to go out to already drilled good hole. Along the direction of two axes shift is less than 10µm, clinometer head position 0 ° . In unit process of cargo bandling, clinometer head is turned round for many times, and all axes are used, those who be is mobile the changeover position to cutting tool. Afore-mentioned numerical value can be achieved on the machine of tall hardness only, well and want to will give out heat the effect that cause is the least change. Through be opposite in rigging a process every component and whole machine undertake continuous quality monitoring, make geometrical error the smallest change. Be worth those who read aloud to note particularly is angle error, when the lengthen cutting tool that if be mentioned in afore-mentioned example,uses, angle error has tremendous effect to the accuracy of inverting. Cutting tool is shorter, gotten result is better. Use those who measure special research and development of head and Mikromat company to survey sample finally (graph 4) is right side horn implement the head undertakes full automatic the electron is corrective. Graph the result that 4 production use also can duplicate: Use at corrective the accuracy that measures the measurement of horny boring milling head to check clinometer head at any time surveys sample reach program of its numerical control to be able to provide an user together, such appearance can detect at any time the accuracy of clinometer head and examination fixed position are sufficient deny orderly, and undertake at the same time corrective. Surveying sample very importantly at wanting to be able to duplicate the result that reach and every result that day production uses. Measure Mikromat the center to measure central complement as Sinumerik for this Mikromat company. Company of Mikromat of have the aid of is producing the experience that undertakes high accuracy is measured below the condition for years, also produce as a result of what solve a bed, make the project technology knowledge of border is able to introduce Nageshi. Will measure a center what inverting treatment should do next to measure union of head RM P60 to apply with radio of Lei Ni carry on namely, pass the inverting error that attends work after complement is corrective for the sake of be in the smallest change. In clinometer head 0 ° are mixed 180 ° locally lay a finger on and the measurement with parallel axis face, then computation goes out to belong to the distance between aperture center position with respective place. The distance school that surveys 0 ° locally is becoming 180 ° locally numeric, and be gotten again greatly. 6b.

The Z that in feeling the 3rd step, mentions to with Y to measure a range. Computation measures the interval between the aperture center position of the quantity with the 5th pace. Clinometer head position 0 ° . 7.

The distance that reachs by the 4th pace and computation of the 6th pace differs a value to adjust null. 8.

Use through adjustment central coordinate by the 7th pace fertile very special boring lever bore, clinometer head position 0 ° . 9.

With measure a computation already the central coordinate of bore. Feel and computation gives two to measure a range respective the distance with aperture center, clinometer head position 0 ° . 10.

the distance theoretical value and real value are made quite. 11.

With measure head plan cipher out to be in the center of 0 ° and bore of place of 180 ° position coordinate. Clinometer head position 0 ° . Direct calculation gives homocentric definition, can repeat piece be less than 0.

The numerical value of 005mm. Summary invests the accurate tool equipment of afore-mentioned introductions, can big the most economic and direct with overhead expenses. Mikromat-V- equipment is the same as full automatic the combination that changes clinometer head is used make 5 treatment can be completed accurately highly below the case that assembles clip in. To the user, the part of treatment is larger, has competitive dominant position is larger. Mikromat company took structure and craft step, the effect that produces calorific effect reduces dinky share. The phase is corrective to the electron, used machinery and calorific measure to achieve bigger result. Temperature change must make equipment is expanded equably point-blank to each direction by the center. Heat expands bend must be eliminated from the structure, because undertake an electron to its corrective be impossible to accomplish actually. In addition, temperature control has conclusive sense. Afore-mentioned circumstances make clear, below the attrib border condition that came true on these Mikromat equipment, electronic dimension examination and adjust improved accuracy further. If good temperature ambient conditions cannot come true, that is all these character do not have a sense. CNC Milling